Energy Saving Oil Filled Transformers
Keywords:
Energy Saving Oil Filled Transformers
产品描述
- 产品描述
-
- Commodity name: Energy Saving Oil Filled Transformers
The coil of each phase is subject to drying, compression, pressure test and height adjustment as per the process to ensure that the height of each coil meets the design requirements. The coils are dried with variable-pressure vacuum drying.
Product description:
The coil of each phase is subject to drying, compression, pressure test and height adjustment as per the process to ensure that the height of each coil meets the design requirements. The coils are dried with variable-pressure vacuum drying.
Advanced test equipment such as chromatographic analyzers and impulse voltage generators are used to ensure the accuracy of test data and the comparability, which ensures that the optimal technical parameters and structural design of each transformer from our company.
Applicable scope:
Including in commercial centers, schools, railways, streetlights, airports, tunnels, subways, power plants
Product model and designation:
Material:
The fully sealed and insulated shell is not easy to rust or corrode,Pure copper coil,Using new silicon steel sheets.
Delivery & Service:
Timely delivery each time. Provide reliable service and responsible for each customer with each product. Our target is to satisfy every customer with the best service.
Technical parameters:
Rated
CapacityVoltage Combination
Winding
Connection GradeNo-load
Loss
(W)Load
Loss
(W)Short
Circuit
Impedance
(%)No-load
Current
(A)High
Voltage
(kV)Tapping Range
Of High Voltage
(%)Low
Voltage
(kV)30
6
6.3
6.6
10
10.5
11±5
±2×2.50.4
Dyn11
100
630
4.0
1.8
50
130
910
1.6
63
150
1090
1.5
80
180
1310
1.5
100
200
1580
1.4
125
240
1890
1.4
160
280
2310
1.3
200
340
2730
1.2
250
400
3200
1.1
315
480
3830
1.1
400
570
4520
1.0
500
680
5430
1.0
630
810
6200
4.5
0.9
OUR ADVANTAGE:
● Reliable operation
We have improved the traditional sealing parts of conservator tanks, providing higher reliability, sealability, and more advanced technique.
● Good performance with overall resistance to moisture and corrosion.
● Protecting the insulation paper and insulation cardboards from oxidation.All prototype products have to go through 4 checks in the whole process:
1. Raw material inspection
2. In processing inspection
3. Final inspection
4. Outgoing inspectionThe transformer body is reliably positioned for ensuring that no dislocation occurs with the transformer and no deformation occurs with the windings during long-distance transportation or during long-term operation. Without the need of core suspension and being maintenance free, this product line may be used just via direct grid connection.