Energy Saving Oil Filled Transformers

The coil of each phase is subject to drying, compression, pressure test and height adjustment as per the process to ensure that the height of each coil meets the design requirements. The coils are dried with variable-pressure vacuum drying.

Keywords:

Energy Saving Oil Filled Transformers

产品描述

  • 产品描述
    • Commodity name: Energy Saving Oil Filled Transformers

    The coil of each phase is subject to drying, compression, pressure test and height adjustment as per the process to ensure that the height of each coil meets the design requirements. The coils are dried with variable-pressure vacuum drying.

    Product description:

    The coil of each phase is subject to drying, compression, pressure test and height adjustment as per the process to ensure that the height of each coil meets the design requirements. The coils are dried with variable-pressure vacuum drying.

    Advanced test equipment such as chromatographic analyzers and impulse voltage generators are used to ensure the accuracy of test data and the comparability, which ensures that the optimal technical parameters and structural design of each transformer from our company.

    Applicable scope:

    Including in commercial centers, schools, railways, streetlights, airports, tunnels, subways, power plants

    Product model and designation:

    11

    Material:

    The fully sealed and insulated shell is not easy to rust or corrode,Pure copper coil,Using new silicon steel sheets.

    Delivery & Service:

    Timely delivery each time. Provide reliable service and responsible for each customer with each product. Our target is to satisfy every customer with the best service.

     

    Technical parameters:

    Rated
    Capacity

    Voltage Combination

    Winding
    Connection Grade

    No-load
    Loss
    (W)

    Load
    Loss
    (W)

    Short
    Circuit
    Impedance
    (%)

    No-load
    Current
    (A)

    High
    Voltage
    (kV)

    Tapping Range
    Of High Voltage
    (%)

    Low
    Voltage
    (kV)

    30

    6
    6.3
    6.6
    10
    10.5
    11

    ±5
    ±2×2.5

    0.4

    Dyn11

    100

    630

    4.0

    1.8

    50

    130

    910

    1.6

    63

    150

    1090

    1.5

    80

    180

    1310

    1.5

    100

    200

    1580

    1.4

    125

    240

    1890

    1.4

    160

    280

    2310

    1.3

    200

    340

    2730

    1.2

    250

    400

    3200

    1.1

    315

    480

    3830

    1.1

    400

    570

    4520

    1.0

    500

    680

    5430

    1.0

    630

    810

    6200

    4.5

    0.9

     

    OUR ADVANTAGE:
    ● Reliable operation
    We have improved the traditional sealing parts of conservator tanks, providing higher reliability, sealability, and more advanced technique.
    ● Good performance with overall resistance to moisture and corrosion.
    ● Protecting the insulation paper and insulation cardboards from oxidation.

     

    All prototype products have to go through 4 checks in the whole process:
    1. Raw material inspection
    2. In processing inspection
    3. Final inspection
    4. Outgoing inspection

    The transformer body is reliably positioned for ensuring that no dislocation occurs with the transformer and no deformation occurs with the windings during long-distance transportation or during long-term operation. Without the need of core suspension and being maintenance free, this product line may be used just via direct grid connection.

     