产品中心


菏泽Energy Saving Underground Distribution Transformers

Low-loss small-and-medium sized oil-immersed transformers up to 35kV class are currently promoted by our company. The products, featuring leading technical parameters and structural design in China, have their unique features and are designed from the perspective of users.

产品描述

Product description:

The products, featuring leading technical parameters and structural design in China, have their unique features and are designed from the perspective of users.

In the structural and technical aspects, the iron core is not perforated and built with 45-degree mitered joints, with the limbs tied with semi-dry unidirectional weftless fiberglass adhesive tapes, having the characteristics of low height and low loss.

Applicable scope:

Including in commercial centers, schools, railways, streetlights, airports, tunnels, subways, power plants

Product model and designation:

11

Material:

The fully sealed and insulated shell is not easy to rust or corrode,Pure copper coil,Using new silicon steel sheets.

Delivery & Service:

Timely delivery each time. Provide reliable service and responsible for each customer with each product. Our target is to satisfy every customer with the best service.

 

Technical parameters:

Rated
Capacity

Voltage Combination

Winding
Connection Grade

No-load
Loss
(W)

Load
Loss
(W)

Short
Circuit
Impedance
(%)

No-load
Current
(A)

High
Voltage
(kV)

Tapping Range
Of High Voltage
(%)

Low
Voltage
(kV)

30

6
6.3
6.6
10
10.5
11

±5
±2×2.5

0.4

Dyn11

100

630

4.0

1.8

50

130

910

1.6

63

150

1090

1.5

80

180

1310

1.5

100

200

1580

1.4

125

240

1890

1.4

160

280

2310

1.3

200

340

2730

1.2

250

400

3200

1.1

315

480

3830

1.1

400

570

4520

1.0

500

680

5430

1.0

630

810

6200

4.5

0.9

 

Pre-drying Treatment
- Low Loss, Low Local Discharges, Low Noise, Strong Heat Radiation, Capable of Running under 150% Nominal Load with the aid of Forced Air Cooling.

 

OUR ADVANTAGE:

1. Long service life

Our transformers have a long service life of 30 years. The conservator tanks of our transformers are fully sealed, bolted or welded to the edge without any clearance, so the oil in the transformers are insulated from air, prolonging the service life.

2. Completely oil-filled and hermetically sealed

It is completely oil-filled and hermetically sealed without a storage tank. The oil volume changes with temperature and load, totally adjusted by the elasticity of the conservator tank, reducing the size of transformers.

3. Protecting the insulation paper and insulation cardboards from oxidation.

 

11

11

11

11

11

11